~ K A L I ~
UNAME : Linux web63.extendcp.co.uk 4.18.0-553.56.1.el8_10.x86_64 #1 SMP Tue Jun 10 05:00:59 EDT 2025 x86_64SERVER IP : 10.0.187.63 -________-
CLIENT IP : 216.73.216.230 MINI SHELL D ZAB '
Current File : //opt/dell/srvadmin/etc/srvadmin-storage/stsvc.ini |
;--------------------------------------------------------------------
;
; Dell Inc. PROPRIETARY INFORMATION
; This software is supplied under the terms of a license agreement or
; non-disclosure agreement with Dell Inc. and may not be copied or
; disclosed except in accordance with the terms of that agreement.
;
; Copyright (c) 1995-2006 Dell Inc.
; All Rights Reserved.
;
;--------------------------------------------------------------------
; General settings
[general]
; Amount, in seconds, to sleep between each attempt to poll the PV20x, PV21x, and PV22x enclosure(s).
EnclosurePollingInterval=30
; nonDellCertified flag for blocking all non-dell certified alerts.
NonDellCertifiedFlag=yes
; Amount, in seconds, to delay at init before attempting to poll the PV20x, PV21x, and PV22x enclosure(s).
EnclosurePollingInitialDelay=30
; Number of failed attempts to communicate with enclosure before an alert is generated.
EnclosureCommunicationLostCount=6
; Enable/disable array disk auto-initializing (Adaptec only).
AdaptecAutoInitializeArrayDisks=Off
; Enable/disable dcomsm.log at startup of the Systems Management Data Manager.
Debug=Off
; Debug Levels in a comma separated list in this order Queue, Ral, Val, AFAVIL, LSIVIL, NRSVIL, EVIL, SASVIL, SASEVIL, HEL, SWRVIL, PSRVIL, RNAVIL, GSMVIL
; DebugLevels will cause all debug data tagged at that level or lower (a level of 3 or higher is the most verbose)
; Debug Level 0 = CRITICAL debug data only
; Debug Level 1 = CRITICAL_INFO
; Debug Level 2 = DEBUG
; Debug Level 3 = INFO
DebugLevels=0,0,0,0,0,0,0,0,0,0,0,0,0,0
;autolog settings
; order tty emm
Autologfilecount=14,5
;Thread stack size limit on esx4i in Kbs
ThreadStackSize=512
; Enable/disable the firmware and driver version check at startup of the Systems Management Data Manager.
DepCheck=On
NRSDepCheck=On
; Enable/disable smart enclosure shutdown - applies to all attached enclosures.
SmartThermalShutdown=Off
; Set RRRWE Threshold for SSDs - SAS/SATA and PCIe SSDs.
RRWEThresholdSasSata=0
RRWEThresholdPCIe=0
; Set Available Spare Threshold for PCIe SSDs.
AvailableSpareWarningThresholdPCIe=10
AvailableSpareCriticalThresholdPCIe=5
SmartAlertPollInterval=1
; Enable/disable initialization of Windows(tm) volumes during virtual disk initialization (LSI only).
EraseWinVolinInitVD=on
; Alert log name
AlertLogName=smalerts.xml
; Amount, in seconds, to sleep after a failed SCSI passthru call (LSI only).
MegaPassthruRetrySleep=2
; Number of attempts to successfully issue a SCSI passthru call (LSI only).
MegaPassthruAttempts=3
; Amount, in minutes, to sleep between refresh of SNMP cached data.
SNMPRefreshMinutes=5
; Enable/disable detection and alert of device problems during Initialization
DetectAndAlert=On
; Amount, in minutes to call the discovery of all VIL's, If 0 then discovery should not happen.
; Minimum minutes to be assigned is 60 minutes(1 hour).
; Note: 60 minutes x 24 hours = 1440 minutes(Recommended value for auto discover is 24 hours)
VilDiscoverIntervalInMinutes=1440
; Startup logic Control
ReportOnStart=On
[sasvil]
; Amount, in seconds, to wait at shutdown for running commands to complete.
TerminateCommandCompleteTimeout=10
; Amount, in seconds, to wait for "create virtual disk" to resolve the new disk to an OS disk.
VDtoOSCorrelationTimeout=30
; Timeout, in milliseconds, for starting threads involved in event notification.
ThreadStartTimeout=60000
; Time, in seconds, to delay before callback if a function fails to set a value.
BtmDelayTime=5
; Startup Event Notification Control
ReportStartUpEvents=On
; Startup Alert Control
ReportAlertsOnStart=On
; SMART alert Polling interval Control for SAS Adapters/Controllers (10 minutes)
SmartIRPollInterval=600
; SMART Alert reminder interval in seconds ( Default: 24 hours/ 86400s) for SAS Adapters/Controllersss
SmartIRRemindInterval=86400
[Multipath]
[ProtectionPolicies]
RAID1=0,0
RAID5=0,0
RAID6=0,0
RAID10=0,0
RAID50=0,0
RAID60=0,0
RAIDALL=0,0
GHS=0,0
IncludeGHSinVDstate=0
; Libraries to be loaded at startup of the Systems Management Data Manager, in order, beginning with entry 0.
[loadvils]
vil0=dsm_sm_lsivil
vil1=dsm_sm_afavil
vil2=dsm_sm_enclvil
vil3=dsm_sm_nrsvil
vil4=dsm_sm_sasvil
vil5=dsm_sm_sasenclvil
vil6=dsm_sm_swrvil
vil7=dsm_sm_psrvil
vil8=dsm_sm_rnavil
vil9=dsm_sm_gsmvil
[SSDSmartInterval]
DAY=1
[VendorID]
Marvell=9
MarvellNVMe=10
storelib8=11
[VendorLibName]
Windows_9=mv_api
Linux_9=libmvraid
Windows_10=BossNvme
Linux_10=libBossNvme
Windows_11=storelib8
Linux_11=libstorelib8
[DependentVendorLibName]
11=HAPI
Coded by KALI :v Greetz to DR HARD ../ kali.zbi@hotmail.com